Overhead Aluminum Conductors

Aluminum conductors used in overhead lines are lightweight and cost-effective. When stranded with steel or aluminum-clad steel wires, the tensile strength of aluminum cables can be significantly enhanced, providing excellent economic value for engineering applications. These conductors are widely used in overhead power transmission and distribution lines, as well as in the terminal of electronic components and enameled wires.

Contact Sales

Key Features

All Aluminum Conductor (AAC)

  • Higher conductivity and lower cost compared to copper cable of the same weight.
  • Lightweight and easy to install.
  • Suitable for overhead transmission and distribution lines, and ground wires and feeder wires of railways.

Aluminum Conductor Steel Reinforced (ACSR)

  • Excellent tensile strength for overhead installation.
  • Longer span installation in uneven areas.
  • Suitable for long-distance overhead transmission and distribution lines, including river crossings and rocky areas, as well as ground wires and feeder wires of railways.

Aluminum Conductor Aluminum-Clad Steel Reinforced (ACSR/AW)

  • Similar structure to ACSR with high tensile strength and lighter weight.
  • High corrosion resistance and higher conductivity than ACSR, resulting in lower power loss.
  • Suitable for long-distance overhead lines and coastal areas, industrial zones, saline lands, and volcanic regions.

Specification of ACSR/AW

Compliance Standards: ASTM B549, TPC A048

ACSR/AW Code Word Conductor Size MCM Stranding No/mm Calculated Sectional Area mm² Overall Diameter mm Weight Kg/M Ultimate Strength kgf
Aluminum AW Wire Aluminum ACSR/AW ACSR/AW AW Core
Hawk/AW 477 26/3.439 7/2.675 241.5 280.8 21.78 8.02 0.930 8,550
Rook/AW 636 24/4.135 7/2.756 322.3 364.1 24.80 8.27 1.170 9,980
Drake/AW 795 26/4.442 7/3.454 402.9 468.5 28.13 10.36 1.551 13,870
Tern/AW 795 45/3.376 7/2.250 402.8 430.6 27.00 6.75 1.301 9,780
Rail/AW 954 45/3.698 7/2.466 483.3 516.8 29.59 7.40 1.562 11,750

Thermal-Resistant Aluminum Conductor Steel Reinforced (TACSR)

  • High tensile strength for installation.
  • Longer span installation in uneven areas.
  • Transmission capacity is 1.4–1.5 times that of ACSR.
  • Suitable for long-distance overhead transmission lines and ground wire and feeder wire of the railway.

Thermal-Resistant Aluminum Conductor Aluminum-Clad Steel Reinforced (TACSR/AW)

  • Same structure as TACSR with high tensile strength and lighter weight.
  • High corrosion resistance and higher conductivity than TACSR, resulting in lower power loss.
  • Transmission capacity is 1.4–1.5 times that of ACSR.
  • Suitable for long-distance overhead transmission and distribution lines in coastal areas, industrial zones, saline lands, and volcanic regions.

Super Thermal-Resistant Aluminum Conductor Aluminum-Clad Steel Reinforced (ZTACIR/AS)

  • Same structure as TACSR with higher tensile strength and lighter weight.
  • High corrosion resistance and higher conductivity than TACSR, resulting in lower power loss.
  • Transmission capacity is 1.6–2.0 times that of ACSR, with lower sag and smaller outer diameter.
  • At the same outer diameter, sag at 210°C for ZTACIR/AS is equivalent to sag at 75°C for ACSR.
  • Suitable for high-capacity, low-sag overhead transmission and distribution lines, and mainly used to replace existing ACSR or ACSR/AW conductors.

Specification of ZTACIR/AS  

Compliance Standards:JEC-3406、JCS-1404、TPC STAW-2

 Type Conductor Size (mm2) Extra-Thermoresistant Aluminum (No/mm) Aluminum-Clad Invar (No/mm) Breaking Strength (kgf) Weight Per m (kg/m (±2%)) Overall Diameter (mm) 210℃ Rated Current  (Amp)
Type A 210 14/3.30 10/3.30 7/3.25 8,830 0.98 19.32 1,070
260 16/3.44 12/3.36 7/3.60 10,850 1.215 21.60 1,240
Type B 310 30/3.66 7/3.66 11,980 1.400 25.62 1,445
340 30/3.8 7/3.8 12,940 1.509 26.60 1,515

Aluminum-Clad Steel Wire (ACW)

  • High tensile strength for installation and excellent corrosion resistance.
  • Suitable for grounding wire applications in coastal, industrial, saline, and volcanic areas.

Specification of ACW

Compliance Standards:ASTM B416-81、TPC WI-5C

Size Nos./AWG Nominal Dia. of Wire (mm)  Stranded Diameter (mm)  Nominal Cross Section (Stranded)(mm2) Conductivity at 20℃ (Min.)(%)     Resistance at 20°C (Max.)(Ω/km)    Breaking Strength (kg)
7/ No 8 3.264 9.79 58.57 20.3 1.4627 7,230
7/ No 6 4.115 12.35 93.10 20.3 0.9197 10,310
7/ No 6 4.115 12.35 93.10 40 0.4667 5,860
19/ No 8 3.264 16.32 158.98 40 0.2750 9,650
19/ No 7 3.665 18.31 200.44 20.3 0.4292 23,460

Features

  • Lightweight & Cost-effective
  • High mechanical strength
  • High conductivity with low transmission loss
  • Excellent weather resistance and corrosion resistance
  • High temperature & ampacity performance

Voltages

69kV~345kV

Applications

Power Transmission & Distribution

Industries

Power

Renewable Energy

Voltages

High

Extra High